+86 13681839278 [email protected]
EN RU

ZRAY Introduces Low Air Consumption Automatic Case Erector (≈95 NL/min, up to 40% Below Industry) for Energy-Efficient Lines | ZRAY

September 16, 2026

Compressed air is the silent cost on most packaging floors: a conventional case erector can draw 180–250 NL/min, and at 0.6 MPa that load forces a bigger compressor, more dryer runtime and a higher bill absent from the machine quotation. ZRAY’s low-air-consumption automatic case erector cuts demand to roughly 95 NL/min — up to 40% below the industry norm — by redesigning the vacuum path rather than simply throttling the line.

Air Consumption Comparison

Model / class Air demand Pressure Compressor load (relative)
Industry conventional erector 180–250 NL/min 0.6 MPa 100% baseline
ZRAY ZR-25S (low-air) ~95 NL/min 0.5–0.6 MPa ~40% lower
ZRAY ZR-40H (double-head) ~150 NL/min 0.5–0.6 MPa ~45% lower

How the Saving Is Engineered

Three design choices deliver the reduction:

  • Vacuum generator over pump — multi-stage ejectors sized to the blank, not a vane or roots pump.
  • Dump circuit — a pilot solenoid bleeds the cup line the instant a blank is released, wasting no air between cycles.
  • Leak control — routed manifolds keep line pressure drop at ≤0.03 MPa, so the compressor does not hunt for setpoint.

Annual Energy Saving Example

One ZR-25S at 95 NL/min vs an industry unit at 220 NL/min, 8 h shift, 250 days/year:

  • Industry: 220 × 60 × 8 × 250 = 26.4 million NL.
  • ZRAY: 95 × 60 × 8 × 250 = 11.4 million NL.
  • Saved: 15.0 million NL/year.
  • At ~0.12 kWh/1,000 NL at 0.6 MPa → ~1,800 kWh/year, about $180–220 at $0.10–0.12/kWh.

Across ten machines the saving reaches ~18,000 kWh and over $2,000 per year, paying back within the first contract. ZRAY logs it under ISO 50001.

Core Specifications

Parameter ZR-25S (Low-Air)
Speed up to 25 CPM
Air demand ~95 NL/min
Air pressure 0.5–0.6 MPa
Power 2.2 kW
Tape 50 mm
Control Delta / Mitsubishi FX5U + 7″ HMI
Carton size L 200–500 / W 150–400 / H 120–450 mm

Corrugated Board Range

Board type Flute profile Layers Thickness Basis weight
Single wall B, C, E 3 3.0–5.0 mm 350–700 gsm
Double wall BC, EB 5 6.0–9.0 mm 700–1,000 gsm
Heavy pre-creased BC 5 up to 11 mm 1,000+ gsm

Flute direction must run vertically on the erected case; board above 9 mm needs pre-creasing and a de-rated 30 CPM.

Field Alarms Linked to the Vacuum Path

Code Description Typical cause Field action
AL-01 Vacuum below −55 kPa Leaking ejector, cracked cup Soap-test fittings, replace cup
AL-03 Pickup miss Worn cup, board warp > 5 mm Replace cup, re-square magazine
AL-09 Air pressure low FRL not drained, line leak Drain FRL, check dump circuit
AL-02 Magazine empty Low stack Reload; set side guides

Preventive Maintenance

Interval Tasks
Daily Drain FRL bowl; verify 0.5–0.6 MPa; clean vacuum filter; inspect suction cups
Weekly Lubricate guides; check belt tension; clean sensors
Monthly Replace vacuum filter element; torque frame bolts
Quarterly Replace suction cups; grease gearbox; verify PLC I/O
Annually Change gearbox oil; insulation-test panel; re-level

Specify a Low-Air Line

For air-constrained floors, start with the Single-Piece Case Erector (95 NL/min), or compare the ZRAY product range for a double-head line.

Get a Quotation for Your Packaging Line

Send us your carton size range, board grade and required CPM — our engineers will return a model recommendation, layout drawing and quotation within 24 hours.

Contact ZRAY: [email protected] · WhatsApp +86 13681839278

Want To Know More About Our Upgraded Machines?

Send your carton specifications and output demand, our engineer will provide free technical scheme & quotation



    Subscribe To Get Latest News & Technical Guides

    Leave your business email to receive free industry articles and new product updates